3.5.2 Connecting the concentric fl ue
Assemble the concentric fl ue system according to one of the examples in section 3.4.1,
fi gure 8 to 14 inclusive.
Distance; heart concentric fl ue to the wall, is 107 mm (minimum 90 mm, maximum
110 mm).
Make sure that all connections are completely gas tight.
3.5.3 Connecting the gas
The gas connection Ø12 mm (3/8”) is located on the back of the appliance.
Use only gas piping with a minimum diameter of 1/2” and a shut-off valve.
Make the connection to the gas supply pipe.
Important: During gas connection, take care not to twist the gas
regulating block. Make sure that both the gas regulating
block and the supply pipes are not subjected to stresses.
After connection of the gas supply, check that all connections are completely gas tight
using soapy water or a leak tester.