Bell System (Telephones) Ltd.
PD-167 Issue 1C 09 October 2014
bell
free
1 Way
Video Door Entry System
With
Hands-free Colour Apartment Stations
Installation & Operation Manual
This manual applies to the following: -
BFD1 Way Door controller Version 1 Builds 1
BF Colour Apartment Station Version 1 Build 1
BS Colour Videophone Version 2 Builds 1 to 3
BSA Audio Phone Version 1 Build 1
Przeglądanie stron 0
1 2 3 4 5 6 ... 43 44

Podsumowanie treści

Strona 1 - Video Door Entry System

Bell System (Telephones) Ltd. PD-167 Issue 1C 09 October 2014 bellfree 1 Way Video Door Entry System With Hands-free Colour Apartment Stations

Strona 2

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 10 of 44 Power Supply Requirements The system is powered by

Strona 3 - TABLE OF CONTENTS

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 11 of 44 Cable Specification. All system wiring must be car

Strona 4 - Introduction

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 12 of 44 Cable Distances Door Controller to BF Apartment St

Strona 5

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 13 of 44 Installation & Commissioning Checklist The fol

Strona 6 - Basic System Operation

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 14 of 44 Apartment Station The apartment station is designe

Strona 7

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 15 of 44 BSA Audio Phone The BSA audio phone can be used as

Strona 8

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 16 of 44 Electric Door Release Both fail-secure and fail

Strona 9 - Design Considerations

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 17 of 44 Commissioning The major components of the bellfree

Strona 10 - Power Supply Requirements

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 18 of 44 BFD1 Door Controller Switch Settings Talking Time/

Strona 11 - Cable Specification

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 19 of 44 Lock Operate Time Dip SW2 (1-3) 3 2 1 Lock Time O

Strona 12 - Cable Distances

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 2 of 44 bellfree Apartment Station BFD1 controller BSA a

Strona 13 - Checklist

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 20 of 44 Camera Numbering DIP SW3 (1-8) Camera 1 at this d

Strona 14 - Flush Mounting

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 21 of 44 Below are a couple of examples and a blank table f

Strona 15

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 22 of 44 Door Speech Volume Adjustment Introduction The spe

Strona 16

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 23 of 44 BF Apartment Station Switch Settings Mute Time Set

Strona 17 - Commissioning

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 24 of 44 BS Videophone Switch Settings Mute Time Settings

Strona 18

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 25 of 44 Troubleshooting Common Faults A very high perce

Strona 19

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 26 of 44 Lock Release Problems Lock release does not oper

Strona 20 - (ASDFGHJK)

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 27 of 44 Speech Problems Loud tone at the entrance sp

Strona 21

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 28 of 44 Specifications BFD1 Door controller Size 185mm x 2

Strona 22 - Build No

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 29 of 44 Model BF-AMP Speech Unit Size 98mm x 60mm x 24mm

Strona 23 - (ASDFTYUI)

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 3 of 44 TABLE OF CONTENTS TABLE OF CONTENTS ...

Strona 24

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 30 of 44 Diagram A – 1 Way Basic System Wiring Overview

Strona 25 - Troubleshooting

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 31 of 44 Diagram B – 1 Way PCB Detail

Strona 26

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 32 of 44 Diagram C – 1 Way Basic System Wiring Detail

Strona 27

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 33 of 44 Diagram D – 1 Way Multiple Entrance Wiring Overvie

Strona 28 - Specifications

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 34 of 44 Diagram E – 1 Way Multiple Entrance Wiring Detail

Strona 29

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 35 of 44 Diagram F – Extension Apartment station Wiring

Strona 30 - 2 x 1mm²

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 36 of 44 Diagram G – Apartment station Local Power Wiring

Strona 31

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 37 of 44 M MM MS SS S- -- -Camera 1 Camera 1Camera 1 Camera

Strona 32 - Door Controller

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 38 of 44 Diagram I – 1 Way DDA Panel Wiring

Strona 33

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 39 of 44 Diagram J – Combined Connections bellfree With Loc

Strona 34 - Apartment

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 4 of 44 Introduction Description A bellfree video door ent

Strona 35 - Note. For each cable run :

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 40 of 44 Diagram J – Continued Connecting a Bellcode Code

Strona 36

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 41 of 44 Diagram K – Combined Connections Third Party Lock

Strona 37 - Cam1 Cam1

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 42 of 44 Diagram K – Continued Connecting a Bellcode Cod

Strona 38 - Extended Panel

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 43 of 44 Safety Information and Declarations Connections to

Strona 39 - With Lock

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 44 of 44 Bell System (Telephones) Ltd. Presley Way, Crown H

Strona 40 - Diagram J – Continued

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 5 of 44 Systembellfree Colour Apartment Station V

Strona 41 - Controller

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 6 of 44 Basic System Operation Call sequence When the call

Strona 42 - Diagram K – Continued

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 7 of 44 Call Privacy Once a call has been made from an entr

Strona 43

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 8 of 44 Multiple Entrances The bellfree system allows multi

Strona 44

BF Apartment Station 1 Way System PD-167 Issue 1C Installation and Operating Manual Page 9 of 44 Design Considerations Equipment List A BF1 one-way