BF Apartment Station Digital Entry System
PD–166 Issue 1 Installation and Operating Manual Page 44 of 48
Diagram L – Combined Connections Third Party Lock
Connecting a Bell PAX1 Proximity Reader
The bellfree door controller is set to fail secure. The diagram assumes a common
power supply, if not an extra wire will be required to connect the PAX1 Exit O to the
bellfree 12V-.
N.B. The power wiring to the PAX1 must be able to carry the lock current with less
than 2V voltage drop.
ACT 1000/2000/3000 Proximity Controller or 100e/200e Extender
Notes
1. Connect the lock release or Maglock using the ACT Manuals.
2. Leave the bellfree controller set to Fail Secure regardless of the type of release used.
3. A normally open exit button can still be fitted to the ACT controller in addition to the
bellfree wiring.
4. If the 2 units are not sharing a power supply, then a connection from bellfree controller
Exit- to ACT 0V will be required.
5. Look for the notes on the ACT installation diagram concerning the use of links when
the door contact is not used and when a power supply without power fail is not used.
PAX1
Proximity
Reader
Exit button
(Optional)
Exit Z
Exit O
Z
O
+
–
Lock
–
Exit button
(Optional)
Supply
IP3
IP2
IP1
0V
OP2
OP3
Lock
+
–
ACT
Push button
Door contact
Aux input
–
Exit